TB Series
-
KAIDELI
-
BITZER
-
Reciprocating Compressor
-
Air-Cooled / Water-Cooled
-
380V / 3 Phase / 50Hz
The TB Series Box Type Condensing Unit is a compact refrigeration condensing unit designed for commercial and industrial refrigeration systems. With an enclosed box-type configuration, the unit provides an integrated solution for refrigeration applications where compact equipment layout, convenient installation, and reliable system operation are important.
The TB Series can be configured for different refrigeration system requirements and is suitable for applications such as cold storage, cold rooms, refrigerated warehouses, food processing, commercial refrigeration, and cold chain refrigeration.
Key Features of the TB Series Box Type Refrigeration Condensing Unit
Compact Box Type Refrigeration Unit
The TB Series features a compact box-type design that integrates key refrigeration equipment into an organized refrigeration system. The enclosed structure helps optimize equipment layout and provides a practical solution for refrigeration installations with limited equipment space.
Reliable Refrigeration Compressor
The refrigeration compressor is a core component of the TB Series condensing unit. Proper compressor selection helps match the refrigeration capacity, evaporating temperature, and operating conditions required by the refrigeration system.
Efficient Refrigeration Condenser
The refrigeration condenser is designed to remove heat from the refrigerant during the condensing process. Proper condenser selection and heat rejection capacity are important for maintaining stable condensing temperature and efficient refrigeration system operation.
Integrated Refrigeration Components
TB Series Box Type Condensing Unit
Interactive 10-Component Modular Breakdown
Enclosed Box Type Design
The enclosed box-type configuration provides an organized equipment layout and helps simplify installation. Compared with a conventional open-type arrangement, the box-type structure offers a more compact solution for many commercial and industrial refrigeration installations.
Flexible Refrigeration System Configuration
The TB Series can be selected according to different refrigeration capacity requirements, operating temperatures, refrigerant configurations, and installation conditions. This makes the condensing unit suitable for a wide range of refrigeration system configurations.
TB Series Refrigeration Condensing Unit Technical Specifications
The technical configuration of the TB Series should be selected according to the refrigeration system requirements and operating conditions.
Medium temperature unit (refrigerant R22) (Bitzer)
TB Series Top-Discharge Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -5℃~5℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | Cap./Power @ -5℃ (kW) | Cap./Power @ -8℃ (kW) | Cap./Power @ -10℃ (kW) | Fan (Power / Current / Speed) | Interface (Suction/Liquid) | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|---|
| TB12M | 4TES-12 | 25.2 | 24.8 / 8.9 | 22.1 / 8.4 | 20.5 / 8.1 | 2×414W / 1.7A / 1300 r/min | φ35 / φ16 | 378 | 1590*805*1990 | 850*775 |
| TB15M | 4PES-15 | 28.2 | 28.4 / 10.2 | 25.2 / 9.6 | 23.3 / 9.2 | 2×414W / 1.7A / 1300 r/min | φ42 / φ16 | 394 | 1590*805*1990 | 850*775 |
| TB20M | 4NES-20 | 33.2 | 33.5 / 11.9 | 29.8 / 11.3 | 27.6 / 10.8 | 2×500W / 1.9A / 1380 r/min | φ42 / φ22 | 406 | 1590*805*1990 | 850*775 |
| TB25M | 4HE-25 | 44.0 | 44.7 / 16.1 | 39.8 / 15.2 | 37.0 / 14.5 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 546 | 1890*905*2190 | 1000*875 |
| TB30M | 4GE-30 | 51.2 | 51.9 / 18.5 | 46.3 / 17.5 | 43.0 / 16.8 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 563 | 1890*905*2190 | 1000*875 |
| TB35M | 4FE-35 | 62.1 | 61.9 / 22.3 | 55.2 / 21.0 | 51.2 / 20.1 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 570 | 1890*905*2190 | 1000*875 |
Medium temperature unit (refrigerant R404A/R507A) (Bitzer)
TB Series Top-Discharge Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -5℃~5℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | Cap./Power @ -5℃ (kW) | Cap./Power @ -8℃ (kW) | Cap./Power @ -10℃ (kW) | Fan (Power / Current / Speed) | Interface (Suction/Liquid) | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|---|
| TB12MY | 4TES-9Y | 19.9 | 23.6 / 10.3 | 21.1 / 9.6 | 19.6 / 9.2 | 2×414W / 1.7A / 1300 r/min | φ35 / φ16 | 376 | 1590*805*1990 | 850*775 |
| TB15MY | 4PES-12Y | 22.7 | 27.0 / 11.4 | 24.0 / 10.7 | 22.3 / 10.2 | 2×414W / 1.7A / 1300 r/min | φ42 / φ16 | 386 | 1590*805*1990 | 850*775 |
| TB20MY | 4NES-14Y | 26.6 | 32.2 / 13.8 | 28.7 / 13.0 | 26.7 / 12.4 | 2×500W / 1.9A / 1380 r/min | φ42 / φ22 | 396 | 1590*805*1990 | 850*775 |
| TB25MY | 4HE-18Y | 36.7 | 43.2 / 18.6 | 38.7 / 17.5 | 36.2 / 16.7 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 530 | 1890*905*2190 | 1000*875 |
| TB30MY | 4GE-23Y | 43.9 | 48.8 / 20.5 | 43.7 / 19.4 | 42.0 / 19.9 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 550 | 1890*905*2190 | 1000*875 |
| TB35MY | 4FE-28Y | 52.8 | 58.4 / 25.6 | 52.5 / 24.2 | 49.7 / 23.7 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 570 | 1890*905*2190 | 1000*875 |
Low temperature unit (refrigerant R404A/R507A) (Bitzer)
TB Series Top-Discharge Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -15℃~-35℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | Cap./Pwr @ -20℃ | Cap./Pwr @ -25℃ | Cap./Pwr @ -30℃ | Cap./Pwr @ -35℃ | Cap./Pwr @ -40℃ | Fan Specs | Suction / Liquid | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TB09LY | 4TES-9Y | 16.5 | 10.8 / 7.4 | 8.6 / 6.4 | 6.7 / 5.4 | 5.1 / 4.4 | 3.7 / 3.6 | 2×205W / 1.02A / 1380rpm | φ35 / φ16 | 319 | 1290*655*1750 | 557*625 |
| TB12LY | 4PES-12Y | 22.7 | 12.1 / 8.1 | 9.5 / 6.9 | 7.3 / 5.8 | 5.5 / 4.7 | 3.8 / 3.8 | 2×205W / 1.02A / 1380rpm | φ35 / φ16 | 321 | 1290*655*1750 | 557*625 |
| TB14LY | 4NES-14Y | 26.6 | 14.7 / 10.0 | 11.7 / 8.6 | 9.1 / 7.2 | 7.0 / 6.0 | 5.0 / 4.9 | 2×205W / 1.02A / 1380rpm | φ35 / φ16 | 323 | 1290*655*1750 | 557*625 |
| TB18LY | 4HE-18Y | 36.7 | 20.7 / 13.8 | 16.7 / 12.0 | 13.2 / 10.3 | 10.2 / 8.7 | 7.4 / 7.3 | 2×414W / 1.7A / 1300rpm | φ42 / φ22 | 436 | 1590*805*1990 | 850*775 |
| TB23LY | 4GE-23Y | 43.9 | 24.2 / 16.4 | 19.7 / 14.3 | 15.7 / 12.2 | 12.3 / 10.4 | 9.1 / 8.7 | 2×414W / 1.7A / 1300rpm | φ54 / φ22 | 456 | 1590*805*1990 | 850*775 |
| TB28LY | 4FES-28Y | 52.8 | 29.0 / 19.7 | 23.5 / 17.1 | 18.8 / 14.7 | 14.7 / 12.4 | 10.8 / 10.3 | 2×500W / 1.9A / 1380rpm | φ54 / φ22 | 476 | 1590*805*1990 | 850*775 |
| TB34LY | 6GE-34Y | 65.5 | 36.4 / 25.0 | 29.7 / 21.8 | 23.8 / 18.8 | 18.8 / 16.0 | 14.0 / 13.5 | 2×800W / 3.2A / 1320rpm | φ54 / φ22 | 575 | 1890*905*2190 | 1000*875 |
| TB44LY | 6FE-44Y | 83.2 | 43.4 / 29.9 | 35.3 / 26.2 | 28.2 / 22.6 | 22.0 / 19.3 | 16.2 / 16.2 | 2×800W / 3.2A / 1320rpm | φ54 / φ22 | 600 | 1890*905*2190 | 1000*875 |
Low temperature quick freezing unit (refrigerant R404A/R507A) (Bitzer)
TB Series Subcooling Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -35℃~-55℃ / Standard Design: Ambient 32°C, Suction Superheat 10K with Subcooling Operation / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | @ -35℃ Cap./Pwr (Liq. T) | @ -40℃ Cap./Pwr (Liq. T) | @ -45℃ Cap./Pwr (Liq. T) | @ -50℃ Cap./Pwr (Liq. T) | @ -55℃ Cap./Pwr (Liq. T) | @ -60℃ Cap./Pwr (Liq. T) | Fan (Power / Current / Speed) | Interface (Suct./Liq.) | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TB05JY | S4T-5.2Y | 14.0 | 5.7 / 4.6 Liq: -0.9℃ | 4.6 / 4.1 Liq: -5.5℃ | 3.7 / 3.6 Liq: -10℃ | 2.9 / 3.2 Liq: -14.7℃ | 2.2 / 2.7 Liq: -19.3℃ | 1.7 / 2.3 Liq: -23.8℃ | 2×205W / 1.02A / 1380 r/min | φ28 / φ12.7 | 313 | 1290*655*1750 | 557*625 |
| TB08JY | S4N-8.2Y | 17.0 | 8.1 / 6.5 Liq: 0℃ | 6.5 / 5.8 Liq: -4.7℃ | 5.2 / 5.2 Liq: -9.4℃ | 4.1 / 4.5 Liq: -14.2℃ | 3.1 / 3.9 Liq: -18.8℃ | 2.4 / 3.3 Liq: -23.4℃ | 2×205W / 1.02A / 1380 r/min | φ28 / φ16 | 323 | 1290*655*1750 | 557*625 |
| TB12JY | S4G-12.2Y | 24.0 | 12.6 / 9.8 Liq: 3.9℃ | 10.4 / 8.8 Liq: -1.1℃ | 8.4 / 7.8 Liq: -6.1℃ | 6.7 / 6.8 Liq: -11℃ | 5.2 / 5.9 Liq: -15.8℃ | 3.9 / 4.9 Liq: -20.6℃ | 2×414W / 1.7A / 1300 r/min | φ35 / φ16 | 366 | 1590*805*1990 | 850*775 |
| TB16JY | S6J-16.2Y | 31.0 | 17.6 / 13.8 Liq: 11.1℃ | 14.6 / 12.3 Liq: 6.1℃ | 11.9 / 10.9 Liq: 0.9℃ | 9.5 / 9.5 Liq: -4.5℃ | 7.4 / 8.3 Liq: -10℃ | 5.7 / 7.0 Liq: -15.7℃ | 2×414W / 1.7A / 1300 r/min | φ42 / φ22 | 468 | 1590*805*1990 | 850*775 |
| TB20JY | S6H-20.2Y | 37.0 | 20.3 / 16.0 Liq: 11.7℃ | 16.8 / 14.3 Liq: 6.6℃ | 13.7 / 12.6 Liq: 1.3℃ | 11.0 / 11.0 Liq: -4.1℃ | 8.6 / 9.6 Liq: -9.7℃ | 6.6 / 8.1 Liq: -15.4℃ | 2×500W / 1.9A / 1380 r/min | φ42 / φ22 | 486 | 1590*805*1990 | 850*775 |
| TB25JY | S6G-25.2Y | 43.0 | 23.1 / 18.4 Liq: 12.3℃ | 19.2 / 16.4 Liq: 7.1℃ | 15.6 / 14.5 Liq: 1.8℃ | 12.5 / 12.7 Liq: -3.7℃ | 9.8 / 11.0 Liq: -9.3℃ | 7.5 / 9.3 Liq: -15.1℃ | 2×800W / 3.2A / 1320 r/min | φ42 / φ22 | 575 | 1890*905*2190 | 1000*875 |
| TB30JY | S6F-30.2Y | 51.0 | 27.3 / 21.9 Liq: 13.3℃ | 22.7 / 19.6 Liq: 8.0℃ | 18.6 / 17.3 Liq: 2.6℃ | 14.9 / 15.2 Liq: -3.0℃ | 11.7 / 13.1 Liq: -8.8℃ | 9.0 / 11.1 Liq: -14.8℃ | 2×800W / 3.2A / 1320 r/min | φ42 / φ22 | 590 | 1890*905*2190 | 1000*875 |
Medium & Low Temperature Refrigeration Operating Range
The TB Series can be selected according to the required evaporating temperature and refrigeration application. Medium-temperature and low-temperature refrigeration systems have different cooling requirements and should be matched with the appropriate compressor and condensing unit capacity.
Medium Temperature Refrigeration Applications
Medium temperature refrigeration is commonly used for refrigerated storage and commercial refrigeration applications where products require controlled temperatures above typical freezing conditions.
Typical applications include:
Cold rooms
Fresh food storage
Refrigerated warehouses
Beverage refrigeration
Commercial refrigeration
Food processing refrigeration
Low Temperature Refrigeration Applications
Low temperature refrigeration systems are designed for applications requiring lower evaporating temperatures and freezing conditions.
Typical applications include:
Frozen food cold storage
Meat and seafood cold storage
Frozen product warehouses
Freezer rooms
Cold chain logistics
Food processing refrigeration
Refrigeration Compressor, Condenser & Integrated Components
A refrigeration condensing unit consists of several important components that work together to reject heat and circulate refrigerant within the refrigeration system.
Refrigeration Compressor
The refrigeration compressor increases refrigerant pressure and circulates refrigerant through the refrigeration cycle. Compressor selection should consider refrigeration capacity, evaporating temperature, condensing temperature, refrigerant type, and operating conditions.
Refrigeration Condenser
The refrigeration condenser transfers heat from the high-pressure refrigerant to the surrounding environment. Condenser capacity should be matched with the compressor and overall refrigeration system requirements.
Liquid Receiver & Refrigeration Accessories
A liquid receiver can provide refrigerant storage within the system and help manage liquid refrigerant during different operating conditions.
Other refrigeration accessories may include:
Filter drier
Sight glass
Solenoid valve
Refrigeration valves and fittings
Refrigeration piping accessories
The exact component configuration should be selected according to the TB Series model and refrigeration system design.
Controls & Protection Components
Pressure switches and refrigeration controls can be used to monitor and protect the refrigeration system. Proper control and protection components help support stable system operation and protect key refrigeration equipment under different operating conditions.
TB Series Box Type Condensing Unit Models & Selection Guide
Selecting the correct TB Series model requires consideration of the refrigeration system's cooling capacity, operating temperature, refrigerant, compressor requirements, and installation environment.
Important selection factors include:
Required refrigeration capacity
Evaporating temperature
Condensing temperature
Refrigerant type
Compressor capacity
Condenser capacity
Ambient temperature
Installation conditions
Electrical requirements
A suitable model should be selected based on the actual refrigeration load and system operating conditions rather than compressor power alone.
TB Series Condensing Unit Dimensions & Installation Requirements
Box Type Condensing Unit Dimensions & Mounting
The TB Series box-type structure is designed for organized installation and equipment integration. Actual dimensions and mounting requirements depend on the selected model and configuration.
The installation location should provide a stable mounting surface and sufficient space for equipment operation, inspection, and maintenance.
Ventilation & Installation Clearance
Adequate ventilation is important for condensing unit operation. The installation area should provide sufficient airflow and clearance around the condenser and other heat-rejection components.
Installation conditions should also consider:
Ambient temperature
Air circulation
Equipment clearance
Maintenance access
Drainage requirements
Refrigeration piping layout
Refrigeration Piping & Electrical Connection
Refrigeration piping should be designed according to the refrigeration capacity, refrigerant, pipe length, pressure drop, and system configuration.
Electrical connections should comply with the applicable electrical requirements and match the selected TB Series model.
TB Series Condensing Unit Applications for Cold Storage & Commercial Refrigeration
The TB Series Box Type Condensing Unit can be used in a variety of temperature-controlled refrigeration applications.
Cold Storage & Cold Rooms
The TB Series can be used as part of refrigeration systems for cold rooms and temperature-controlled storage facilities.
Refrigerated Warehouses
Refrigerated warehouses require reliable refrigeration equipment to maintain controlled storage temperatures. The appropriate TB Series configuration can be selected according to the warehouse refrigeration load and operating temperature.
Food Processing Refrigeration
Food processing facilities often require refrigeration for raw materials, processed products, and temperature-controlled production areas. The TB Series can be integrated into refrigeration systems for different processing applications.
Meat & Seafood Cold Storage
Meat and seafood storage requires controlled refrigeration conditions to maintain product quality. Proper refrigeration capacity and low-temperature system configuration are important for these applications.
Cold Chain Logistics
Cold chain logistics facilities require stable refrigeration throughout storage and distribution processes. The TB Series can be used in refrigeration systems for temperature-controlled warehouses and related cold chain applications.
Commercial Refrigeration
The TB Series can also be applied to commercial refrigeration systems, including refrigerated storage areas, food retail facilities, and other temperature-controlled commercial applications.
Industrial Refrigeration Systems
For industrial refrigeration applications, condensing unit selection should consider refrigeration capacity, operating temperature, ambient conditions, refrigerant requirements, and continuous operating requirements.
Box Type vs Open Type Condensing Unit: Which Is Right for Your Refrigeration System?
Box Type Condensing Unit
A box-type condensing unit integrates refrigeration equipment into an enclosed structure. This configuration can provide a compact equipment arrangement and is suitable for installations where organized equipment layout is important.
Open Type Condensing Unit
An open-type condensing unit typically provides more accessible visibility and access to individual refrigeration components. It can be suitable for applications where frequent maintenance, component access, or flexible equipment arrangements are required.
Choosing the Right Condensing Unit Design
The choice between a box-type and open-type condensing unit depends on the refrigeration system design, installation environment, maintenance requirements, available space, and equipment configuration.
How to Select the Right Condensing Unit for Your Refrigeration System
Determine Required Refrigeration Capacity
Calculate the required refrigeration capacity based on room dimensions, product load, ambient conditions, door openings, insulation, pull-down requirements, and other heat loads.
Select the Appropriate Evaporating Temperature
The required evaporating temperature depends on the target storage or operating temperature. Medium-temperature and low-temperature refrigeration systems require different refrigeration configurations.
Choose the Refrigerant
Refrigerant selection should consider system design, operating temperature, refrigeration capacity, applicable regulations, and equipment compatibility.
Match Compressor & Condenser Capacity
The refrigeration compressor and condenser should be properly matched to provide the required cooling capacity and heat rejection performance under the expected operating conditions.
Consider Ambient Temperature & Installation Conditions
Ambient temperature, ventilation, installation location, altitude, maintenance space, and electrical conditions can all affect condensing unit performance.
Why Choose KAIDELI as Your Refrigeration Equipment Manufacturer?
Professional Refrigeration Equipment Manufacturing
KAIDELI focuses on refrigeration equipment and refrigeration system solutions for commercial and industrial applications.
Box Type Condensing Unit Solutions
KAIDELI provides box-type condensing unit solutions designed for different refrigeration applications and system configurations.
Integrated Refrigeration Components
A properly configured condensing unit brings together the refrigeration compressor, condenser, controls, and required refrigeration accessories to support efficient system integration.
Customized Refrigeration Solutions
Different refrigeration projects have different cooling capacity, temperature, refrigerant, installation, and operating requirements. KAIDELI can provide refrigeration equipment solutions according to specific project requirements.
Technical Support & After-Sales Service
Technical support can help customers with condensing unit selection, refrigeration system configuration, installation requirements, and equipment operation.
TB Series Box Type Condensing Unit FAQs
What is a TB Series Box Type Condensing Unit?
The TB Series Box Type Condensing Unit is an enclosed refrigeration condensing unit designed for commercial and industrial refrigeration systems. It provides a compact equipment configuration for different refrigeration applications.
What applications can the TB Series Condensing Unit be used for?
The TB Series can be used in refrigeration systems for cold storage, cold rooms, refrigerated warehouses, food processing, meat and seafood storage, cold chain logistics, commercial refrigeration, and industrial refrigeration applications.
What components are included in the TB Series?
The exact component configuration depends on the selected TB Series model. A refrigeration condensing unit may include a refrigeration compressor, refrigeration condenser, liquid receiver, filter drier, sight glass, solenoid valve, pressure switch, and refrigeration controls & accessories.
Is the TB Series suitable for medium-temperature refrigeration?
The TB Series can be configured for refrigeration applications according to the required evaporating temperature and refrigeration capacity. The actual operating range should be confirmed according to the selected model and technical specification.
Is the TB Series suitable for low-temperature refrigeration?
The TB Series can be configured for low-temperature refrigeration applications when the selected model and compressor configuration meet the required operating conditions.
How do I choose the right TB Series model?
Model selection should consider refrigeration capacity, evaporating temperature, condensing temperature, refrigerant, compressor capacity, condenser capacity, ambient temperature, installation conditions, and electrical requirements.
Keep in touch with us
Looking for the right refrigeration equipment for your cold storage project? Contact our team for product information, technical support, and a suitable refrigeration solution for your application.
Mob:+86-159 6116 8909
E-mail:aaron@freezercold.com