
-
BF Series
-
KAIDELI
-
BITZER
-
Reciprocating Compressor
-
Air-Cooled / Water-Cooled
-
380V / 3 Phase / 50Hz
The BF Series Box Type Condensing Unit is a compact refrigeration condensing unit designed for commercial and industrial refrigeration systems. Its enclosed box-type structure integrates key refrigeration components into a practical and space-saving configuration, making it suitable for different refrigeration system requirements.
The BF Series can be applied to cold storage, cold rooms, refrigerated warehouses, food processing refrigeration, cold chain refrigeration, and commercial refrigeration projects. Its box-type configuration helps provide a convenient solution where an integrated refrigeration unit is preferred.
BF Series Box Type Condensing Unit
Interactive 8-Component Modular Breakdown
Refrigeration Compressor
The refrigeration compressor is a core component of the BF Series refrigeration system. Compressor configuration can be selected according to the required refrigeration capacity, evaporating temperature, refrigerant, and application conditions.
Key Features of the BF Series Box Type Refrigeration Condensing Unit
Compact Box Type Refrigeration Unit
The BF Series features an enclosed box-type configuration that integrates major refrigeration components into a compact refrigeration unit. This design is suitable for projects where equipment organization, installation convenience, and efficient use of available space are important.
Reliable Refrigeration Compressor
The refrigeration compressor provides the compression function required by the refrigeration cycle. The compressor configuration can be matched with the required cooling capacity and operating conditions of the refrigeration system.
Efficient Refrigeration Condenser
The refrigeration condenser is designed to reject heat from the refrigeration cycle. Depending on the system configuration, the condenser selection should match the refrigeration capacity, condensing temperature, ambient conditions, and installation environment.
Integrated Refrigeration Components
The BF Series Box Type Condensing Unit integrates key refrigeration components into a compact box-type structure, providing a complete and reliable refrigeration power system for commercial and industrial cooling applications. The integrated design simplifies installation, improves system organization, and facilitates routine maintenance.
Enclosed Box Type Design
The enclosed structure provides an organized equipment layout and helps simplify the overall refrigeration system configuration. It is particularly suitable for applications where a compact and integrated box type condensing unit is preferred.
Flexible Refrigeration System Configuration
The BF Series can be configured according to different refrigeration requirements, including medium-temperature and low-temperature refrigeration applications. Component selection can be adjusted according to the required refrigeration capacity, refrigerant, evaporating temperature, and installation conditions.
BF Series Refrigeration Condensing Unit Technical Specifications
The technical configuration of the BF Series depends on the selected model and refrigeration application. Key parameters may include compressor model, refrigerant, refrigeration capacity, evaporating temperature, condensing temperature, motor power, power supply, dimensions, and weight.
High temperature unit (refrigerant R22 & R404A/R507A) (Frascold)
BF Series Reciprocating Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: 8℃~15℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | R22 Cap./Power (kW) 10℃ / 5℃ / 0℃ | R404A/R507A Cap./Power (kW) 7.5℃ / 5℃ / 0℃ | Fan (Power / Current / Speed) | Interface (Suction/Liquid) | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|
| BF04HY | D4-18.1Y | 12.5 | 18.5/4.4 | 15.9/4.2 | 13.5/4.0 | / | 15.2/5.6 | 13.1/5.1 | 2×205W / 1.02A / 1380 r/min | φ28 / φ12.7 | 178 | 1290*655*1050 | 557*625 |
| BF05HY | Q5-24.1Y | 13.8 | 24.3/6.0 | 20.9/5.7 | 17.8/5.3 | / | 20.4/6.6 | 17.4/6.1 | 2×205W / 1.02A / 1380 r/min | φ28 / φ16 | 206 | 1290*655*1050 | 557*625 |
| BF07HY | Q7-28.1Y | 17.6 | 29.5/6.7 | 25.3/6.5 | 21.5/6.1 | / | 24.3/8.1 | 20.9/7.4 | 2×414W / 1.7A / 1300 r/min | φ35 / φ16 | 250 | 1590*805*1190 | 850*775 |
| BF12HY | S12-42Y | 22.4 | 44.4/10.2 | 38.0/9.6 | 32.3/8.9 | / | 35.1/11.1 | 29.9/10.1 | 2×800W / 3.2A / 1320 r/min | φ35 / φ16 | 365 | 1890*905*1340 | 1000*875 |
| BF15HY | S15-52Y | 32.4 | 55.9/12.4 | 47.9/11.6 | 40.7/10.7 | 48.0/15.1 | 45.3/14.3 | 38.8/13.2 | 2×800W / 3.2A / 1320 r/min | φ42 / φ22 | 372 | 1890*905*1340 | 1000*875 |
| BF20HY | S20-56Y | 38.4 | 59.9/14.4 | 50.9/13.4 | 43.3/12.4 | 52.6/16.9 | 49.8/16.0 | 42.7/14.7 | 2×800W / 3.2A / 1320 r/min | φ42 / φ22 | 385 | 1890*905*1340 | 1000*875 |
Medium temperature unit (refrigerant R22 & R404A/R507A) (Frascold)
BF Series Reciprocating Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -5℃~5℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | R22 Cap./Power (kW) -5℃ / -8℃ / -10℃ | R404A/R507A Cap./Power (kW) -5℃ / -8℃ / -10℃ | Fan (Power / Current / Speed) | Interface (Suction/Liquid) | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|
| BF04MY | D4-18.1Y | 12.5 | 10.7/4.0 | 9.6/3.8 | 9.0/3.7 | 10.1/5.0 | 9.2/4.7 | 8.6/4.6 | 2×205W / 1.02A / 1380 r/min | φ28 / φ12.7 | 172 | 1290*655*1050 | 557*625 |
| BF05MY | Q5-24.1Y | 13.8 | 14.0/5.3 | 12.5/5.0 | 11.6/4.8 | 13.2/5.9 | 11.8/5.6 | 11.0/5.4 | 2×205W / 1.02A / 1380 r/min | φ28 / φ12.7 | 203 | 1290*655*1050 | 557*625 |
| BF07MY | Q7-28.1Y | 17.6 | 16.9/6.1 | 15.1/5.8 | 14.1/5.6 | 15.9/7.2 | 14.3/6.8 | 13.4/6.5 | 2×205W / 1.02A / 1380 r/min | φ35 / φ12.7 | 203 | 1290*655*1050 | 557*625 |
| BF12MY | S12-42Y | 22.4 | 25.3/8.7 | 22.6/8.3 | 21.1/7.9 | 22.6/9.7 | 20.2/9.1 | 18.9/8.6 | 2×414W / 1.7A / 1300 r/min | φ35 / φ16 | 290 | 1590*805*1190 | 850*775 |
| BF15MY | S15-52Y | 32.4 | 31.8/10.5 | 28.3/9.9 | 26.3/9.5 | 29.9/12.9 | 27.0/12.2 | 25.3/11.6 | 2×414W / 1.7A / 1300 r/min | φ42 / φ16 | 305 | 1590*805*1190 | 850*775 |
| BF20MY | S20-56Y | 38.4 | 34.1/12.0 | 30.8/11.4 | 28.8/10.9 | 32.9/14.2 | 29.7/13.4 | 27.9/12.8 | 2×500W / 1.9A / 1380 r/min | φ42 / φ22 | 320 | 1590*805*1190 | 850*775 |
| BF25MY | V25-71Y | 43.5 | 42.1/14.5 | 38.0/13.8 | 35.5/13.2 | 39.8/17.5 | 35.6/16.5 | 33.2/15.9 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 440 | 1890*905*1340 | 1000*875 |
| BF30MY | V30-84Y | 49.2 | 49.4/17.5 | 44.6/16.6 | 41.7/15.9 | 48.1/20.9 | 43.1/19.7 | 40.3/18.9 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 452 | 1890*905*1340 | 1000*875 |
| BF35MY | V35-103Y | 61.0 | 60.1/21.1 | 54.6/20.1 | 51.4/19.4 | 56.9/27.8 | 51.3/26.0 | 48.1/24.8 | 2×800W / 3.2A / 1320 r/min | φ54 / φ22 | 465 | 1890*905*1340 | 1000*875 |
Low temperature unit (refrigerant R404A/R507A) (Frascold)
BF Series Reciprocating Condensing Unit (Power Supply: 3PH/380V/50Hz / Storage Temp: -15℃~-35℃ / Standard Design: Ambient 32°C, Suction Superheat 10K / Fan Voltage: 3PH/380V/50Hz)
| Unit Model | Compressor | Max. A | Cap./Pwr @ -20℃ | Cap./Pwr @ -25℃ | Cap./Pwr @ -30℃ | Cap./Pwr @ -35℃ | Cap./Pwr @ -40℃ | Fan Specs | Suction / Liquid | Weight (kg) | Dimensions (L*W*H) | Install Dim. (a*b) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BF04LY | Q4-24.1Y | 11.7 | 6.1 / 4.4 | 4.9 / 3.8 | 3.9 / 3.3 | 2.9 / 2.8 | 2.1 / 2.3 | 2×205W / 1.02A / 1380rpm | φ28 / φ12.7 | 200 | 1290*655*1050 | 557*625 |
| BF05LY | Q5-33.1Y | 14.4 | 9.0 / 6.6 | 7.4 / 5.7 | 5.9 / 4.8 | 4.6 / 4.1 | 3.5 / 3.4 | 2×205W / 1.02A / 1380rpm | φ35 / φ12.7 | 200 | 1290*655*1050 | 557*625 |
| BF08LY | S8-42Y | 20.3 | 11.7 / 7.8 | 9.5 / 6.8 | 7.5 / 5.8 | 5.8 / 4.8 | 4.2 / 3.9 | 2×205W / 1.02A / 1380rpm | φ35 / φ16 | 245 | 1290*655*1050 | 557*625 |
| BF10LY | S10-52Y | 24.5 | 14.7 / 10.1 | 12.1 / 8.7 | 9.8 / 7.4 | 7.7 / 6.3 | 5.8 / 5.2 | 2×205W / 1.02A / 1380rpm | φ35 / φ16 | 250 | 1290*655*1050 | 557*625 |
| BF15LY | V15-71Y | 32.2 | 19.9 / 14.0 | 16.3 / 12.0 | 13.2 / 10.2 | 10.3 / 8.5 | 7.7 / 7.0 | 2×414W / 1.7A / 1300rpm | φ42 / φ16 | 350 | 1590*805*1190 | 850*775 |
| BF20LY | V20-84Y | 42.6 | 22.5 / 15.8 | 18.4 / 13.7 | 14.7 / 11.7 | 11.4 / 9.9 | 8.5 / 8.2 | 2×414W / 1.7A / 1300rpm | φ42 / φ22 | 368 | 1590*805*1190 | 850*775 |
| BF25LY | V25-103Y | 52.3 | 28.2 / 21.0 | 22.6 / 18.1 | 17.7 / 15.4 | 13.5 / 12.9 | 9.8 / 10.8 | 2×500W / 1.9A / 1380rpm | φ54 / φ22 | 385 | 1590*805*1190 | 850*775 |
| BF30LY | Z30-126Y | 55.7 | 33.6 / 22.8 | 27.1 / 19.8 | 21.4 / 16.9 | 16.4 / 14.2 | 12.1 / 11.7 | 2×800W / 3.2A / 1320rpm | φ54 / φ22 | 485 | 1890*905*1340 | 1000*875 |
| BF40LY | Z40-154Y | 77.9 | 44.1 / 30.3 | 36.3 / 26.1 | 29.4 / 22.2 | 23.1 / 18.6 | 17.2 / 15.4 | 2×800W / 3.2A / 1320rpm | φ54 / φ22 | 510 | 1890*905*1340 | 1000*875 |
Medium & Low Temperature Refrigeration Operating Range
The BF Series can be configured for different refrigeration operating conditions according to the selected compressor, refrigerant, condenser, and refrigeration system requirements.
Medium Temperature Refrigeration
Medium-temperature refrigeration systems are commonly used for applications where products need to be maintained above freezing temperatures. Typical applications include cold rooms, refrigerated storage, food processing, supermarkets, and commercial refrigeration systems.
The required evaporating temperature and refrigeration capacity should be determined according to the actual product load, room temperature, ambient conditions, and refrigeration system design.
Low Temperature Refrigeration
Low-temperature refrigeration is commonly used for applications requiring lower storage temperatures, including frozen food storage and other low-temperature cold storage applications.
For low-temperature refrigeration, compressor selection, refrigerant selection, refrigeration capacity, evaporating temperature, and condenser capacity should be properly matched to the system requirements.
Refrigeration Compressor, Condenser & Integrated Components
Refrigeration Compressor
The refrigeration compressor is responsible for circulating and compressing refrigerant within the refrigeration cycle. Proper compressor selection should consider refrigeration capacity, evaporating temperature, condensing temperature, refrigerant type, and operating conditions.
Refrigeration Condenser
The refrigeration condenser transfers heat from the refrigerant to the surrounding environment or cooling medium. The appropriate condenser selection depends on the required refrigeration capacity, condensing temperature, ambient temperature, and cooling configuration.
Liquid Receiver & Refrigeration Accessories
Depending on the configuration, the refrigeration system may include a liquid receiver, filter drier, sight glass, solenoid valve, and other refrigeration accessories. These components support refrigerant management and system operation.
Controls & Protection Components
Refrigeration controls and protection components can include pressure switches and other control devices selected according to the refrigeration system configuration. Proper control and protection help support reliable operation of the condensing unit.
BF Series Box Type Condensing Unit Models & Selection Guide
Selecting the appropriate BF Series model requires consideration of the refrigeration system's operating conditions and application requirements.
Important selection factors include:
Required refrigeration capacity
Refrigeration application
Medium-temperature or low-temperature operation
Evaporating temperature
Condensing temperature
Refrigerant type
Compressor model
Condenser configuration
Ambient temperature
Installation conditions
Power supply requirements
For accurate condensing unit selection, the refrigeration load and operating conditions should be determined before selecting the appropriate compressor and condenser configuration.
BF Series Condensing Unit Dimensions & Installation Requirements
Box Type Condensing Unit Dimensions & Mounting
The dimensions and mounting requirements vary according to the selected BF Series model and configuration. Sufficient space should be provided around the refrigeration equipment for installation, inspection, and maintenance.
Ventilation & Installation Clearance
For air-cooled refrigeration systems, adequate ventilation and airflow are important for effective heat rejection. The installation location should provide sufficient clearance around the condenser and avoid unnecessary obstruction of airflow.
Refrigeration Piping & Electrical Connection
Refrigeration piping should be designed according to the selected refrigeration system configuration, refrigerant, pipe length, and operating conditions. Electrical connections should follow the specified power supply and local electrical requirements.
BF Series Condensing Unit Applications for Cold Storage & Commercial Refrigeration
Cold Storage & Cold Rooms
The BF Series can be used in cold storage and cold room refrigeration systems for maintaining controlled storage temperatures for different products.
Refrigerated Warehouses
For refrigerated warehouses, the condensing unit can be integrated with an appropriate refrigeration system to support temperature-controlled storage and distribution.
Food Processing Refrigeration
Food processing facilities require reliable temperature control during processing, temporary storage, and handling. The BF Series can be configured according to the refrigeration requirements of different food processing applications.
Meat & Seafood Cold Storage
Meat and seafood storage commonly requires controlled refrigeration temperatures. The appropriate BF Series configuration can be selected according to the required storage temperature and refrigeration load.
Cold Chain Logistics
The BF Series can be applied to cold chain refrigeration systems used for temperature-controlled storage and distribution of refrigerated and frozen products.
Commercial Refrigeration
The BF Series can also be used in commercial refrigeration applications such as refrigerated storage areas and other temperature-controlled commercial facilities.
Industrial Refrigeration Systems
For industrial refrigeration applications, the BF Series can be configured according to the required refrigeration capacity, operating temperature, refrigerant, and system design.
Box Type vs Open Type Condensing Unit: Which Is Right for Your Refrigeration System?
Box Type Condensing Unit
A box type condensing unit integrates major refrigeration components into an enclosed structure. It can be suitable for projects where a compact and organized refrigeration equipment configuration is required.
Open Type Condensing Unit
An open type condensing unit generally provides easier access to individual refrigeration components for inspection and maintenance. It can be suitable for refrigeration projects where accessibility and flexible component arrangement are important.
Choosing the Right Condensing Unit Design
The choice between a box type and open type condensing unit depends on the project requirements, installation environment, maintenance preferences, available space, refrigeration capacity, and overall refrigeration system configuration.
How to Select the Right Condensing Unit for Your Refrigeration System
Determine Required Refrigeration Capacity
Calculate the required refrigeration capacity based on room volume, product load, heat infiltration, door openings, ambient conditions, insulation, and other heat loads.
Select the Appropriate Evaporating Temperature
The evaporating temperature should correspond to the required room or product temperature and the characteristics of the refrigeration application.
Choose the Refrigerant
Refrigerant selection should consider the required operating temperature, system design, applicable regulations, efficiency requirements, and equipment compatibility.
Match Compressor & Condenser Capacity
The refrigeration compressor and condenser should be properly matched to the required cooling capacity and operating conditions. An appropriate compressor selection and condenser selection helps ensure the refrigeration system is properly configured.
Consider Ambient Temperature & Installation Conditions
Ambient temperature, installation location, ventilation, airflow, electrical supply, piping distance, and maintenance access should all be considered during condensing unit selection.
Why Choose KAIDELI as Your Refrigeration Equipment Manufacturer?
Professional Refrigeration Equipment Manufacturing
KAIDELI focuses on refrigeration equipment and refrigeration condensing unit solutions for different commercial and industrial applications.
Box Type Condensing Unit Solutions
The BF Series provides a box-type configuration for refrigeration projects requiring an integrated and compact condensing unit solution.
Quality Refrigeration Components
Appropriate refrigeration compressors, condensers, controls, and other refrigeration components can be configured according to project requirements.
Customized Refrigeration Solutions
Different refrigeration applications may require different refrigeration capacities, operating temperatures, refrigerants, and component configurations. KAIDELI can provide refrigeration equipment solutions based on specific system requirements.
Technical Support & After-Sales Service
Technical support can assist customers with model selection, refrigeration system configuration, installation requirements, and other equipment-related questions.
BF Series Box Type Condensing Unit FAQs
What is a BF Series Box Type Condensing Unit?
The BF Series Box Type Condensing Unit is an enclosed refrigeration condensing unit designed for commercial and industrial refrigeration applications. It integrates key refrigeration components into a compact box-type configuration.
What is the difference between a box type and open type condensing unit?
A box type condensing unit uses an enclosed structure to organize major refrigeration components, while an open type condensing unit provides a more accessible component layout. The appropriate design depends on the installation environment and refrigeration system requirements.
What temperature range does the BF Series Condensing Unit support?
The BF Series can be configured for medium-temperature and low-temperature refrigeration applications. The actual operating range depends on the selected model, compressor, refrigerant, evaporating temperature, and system configuration.
What refrigeration components are included in the BF Series?
Depending on the selected configuration, the BF Series may include a refrigeration compressor, refrigeration condenser, liquid receiver, filter drier, sight glass, solenoid valve, pressure switch, and other refrigeration controls and accessories.
Is the BF Series suitable for cold storage?
Yes. The BF Series can be configured for cold storage, cold rooms, refrigerated warehouses, and other temperature-controlled refrigeration applications, subject to the required refrigeration capacity and operating conditions.
How do I choose the right BF Series model?
Model selection should consider refrigeration capacity, evaporating temperature, condensing temperature, refrigerant, compressor configuration, condenser configuration, ambient temperature, installation conditions, and power supply requirements.
Keep in touch with us
Looking for the right refrigeration equipment for your cold storage project? Contact our team for product information, technical support, and a suitable refrigeration solution for your application.
Mob:+86-159 6116 8909
E-mail:aaron@freezercold.com

